0355st measurements

The measurements have been made after the circuit has been operated for one hour at room temperature approximately 25°C.

We have 290 V on the C9 filter capacitor instead of 310 V, maybe because our mains transformer has higher internal resistance than the one used in the Philips EZ81 graphs, which was our reference for the power supply calculations.

In my prototype I have tried using a higher voltage transformer, but the voltages of the circuit were too high, and I finally decided to use the 370DAX.

The output transformer also doesn’t have the same primary winding resistance as the one used in the original circuit. We have

Rp = (310 – 290) / 45 = 444 Ω

in the original transformer versus 350 Ω measured in the 125BSE. It was necessary to change the value of the resistor R8 from 3.9 kΩ to 2.2 kΩ to equalize the plate and screen voltages of V2.

Total power consumption

Mains AC total power consumption was 245 mA over 230 V 50 Hz. That’s about 56 watts.

Voltages

Point of measurement Original 0355st
TR1 sec with no load 300 – 0 – 300 Vac 287 – 0 – 287 Vac
TR1 sec 270 – 0 – 270 Vac
TR1 fil 6.3 Vac 6.3 Vac
C9 310 Vdc 290 Vdc
C6 290 Vdc 275 Vdc
C3 210 Vdc 200 Vdc
V2a 290 Vdc 275 Vdc
V2s 290 vdc 275 Vdc
V2k 28 Vdc 28 Vdc
V1a 20 Vdc 20 Vdc
V1s 28 Vdc 27 Vdc
V1k 17.5 mVdc

DC Currents (based on calculations from voltages)

Point of measurement Original 0355st
R12 5.13 mA 6.82 mA
V2a 45.08 mA 43.37 mA
V2s 4.92 mA 6.63 mA
V2k 50.00 mA 50.00 mA
V1a 0.21 mA 0.19 mA
V1k 0.21 mA
Total per channel 50,21 mA 50,19 mA

Graphs

We can calculate the output power

P = U2 / RLOAD = 1322 / 5000 = 3.48 WRMS

For an input of 100 mV, the output is 132 V. Hence the output is 132 / 0.1 = 1320 times as great as the input.

The gain of V1 is 3.33 / 0.1 = 33.3

the gain of V2 is 132 / 3.33 = 39.64

and the total voltage gain is 33.3 x 39.64 = 1320

When we increase the input voltage, we will have great distortion already in the first tube V1 as you can see in the following graph

Frequency response

Start up voltages